↓ Skip to main content

Testing Local AI Models, Part 2

loading

Testing Local AI Models, Part 2: Revised Conclusion
#

1. Scope and interpretation
#

This round compares Nemotron 3.5 Bolt E4B Q4_K_M, the same model using DFlash speculative decoding, and Qwen3.5 4B Q6_K against the Gemma 4 E2B and Gemma 4 E4B baseline results from Part 1. The comparison covers six distinct tasks: a fruit-box logic puzzle, a constrained essay, a tightly specified explanation of rust formation, radical-pair spin chemistry, the 1,000-bottle puzzle, and a proposed computational investigation of magnetic-field effects on chemical systems.

The writing prompt appears twice in the test material with identical answers and timings, and repeated material for the bottle puzzle and magnetic-field task is not counted as additional trials. Each of the six task categories is therefore counted once. The reasoning-enabled responses form the basis of the comparative scores and elapsed-time table below. The source also records reasoning-disabled responses for the new model configurations; those are marked Instant, but they are not assigned a separate score series in the existing evaluation. “Instant” is the recorded interface label, not a measured zero-second latency.

Scores are subjective evaluations of the supplied answers, not universal ratings of model capability. Each task is scored out of 10, and the overall score is the unweighted mean of the six task scores. The Gemma baseline scores are carried over from Part 1 so that the comparison retains the original scoring scale. Because the evaluations are based on a small set of single-run responses, small score differences should be treated as indicative rather than statistically significant.

The recorded environment was an ASUS Creator Q540VJ with an Intel Core i9-13900H, 16 GB DDR5-4800 RAM, and an NVIDIA RTX 3050 with 6 GB VRAM. The original benchmark was run in LM Studio Bionic 1.1.9-6 using default settings. The times below are elapsed response times, not token-per-second measurements. The reasoning-enabled runs are used for the timed comparison.

Model Quantization
Gemma 4 E4B — baseline Q4_K_M
Gemma 4 E2B — baseline Q4_K_M
Nemotron 3.5 Bolt E4B Q4_K_M
Nemotron 3.5 Bolt E4B + DFlash Q4_K_M
Qwen3.5 4B Q6_K

2. Overall results
#

Model / configuration Logic Writing Rust / instructions Radical chemistry Bottle puzzle Magnetic-field research Average
Gemma 4 E4B — baseline 9.5 8.5 4.0 7.5 9.0 6.0 7.42
Gemma 4 E2B — baseline 9.5 8.5 5.0 4.5 6.5 6.0 6.67
Nemotron 3.5 Bolt E4B 9.5 8.5 7.5 5.5 9.5 4.0 7.42
Nemotron 3.5 Bolt E4B + DFlash 9.5 8.0 6.5 6.5 8.5 3.0 7.00
Qwen3.5 4B 7.5 7.5 6.5 7.0 7.5 2.5 6.42

The expanded six-task comparison changes the interpretation of the earlier, narrower assessment. Standard Nemotron 3.5 Bolt E4B ties Gemma 4 E4B at 7.42/10, making it a genuine overall contender rather than simply a fast alternative. Nemotron with DFlash scores 7.00/10, 0.33 points above Gemma 4 E2B at 6.67. Qwen3.5 4B scores 6.42/10: its radical-chemistry explanation is comparatively useful, but its weak magnetic-field proposal and avoidable reasoning or encoding errors hold down its overall result.

The averages conceal substantial differences between task categories. Standard Nemotron is particularly strong in logic, instruction following, and the bottle puzzle, but it is much weaker in radical spin chemistry and magnetic-field research. DFlash is similarly uneven. An overall tie with Gemma E4B therefore does not imply equivalent performance in every domain, especially not in the scientific work that motivates this benchmark.

3. What the six tests revealed
#

Test 1 — Logic: the fruit-box puzzle
#

The task asks which incorrectly labelled box should be sampled when every label is wrong, and how one sampled fruit can determine the contents of all three boxes. The decisive observation is that the box labelled “Apples & Oranges” cannot actually contain a mixture. A single fruit drawn from it therefore identifies it as the all-apples or all-oranges box; the other two boxes can then be deduced by elimination.

Both Nemotron configurations identify the correct box and complete the deduction for either possible fruit. Their answers are clear and logically complete, matching the high Gemma baseline on this task. Qwen reaches the correct final arrangement for the apple-drawn case, but its explanation skips an important step: after identifying the sampled box as apples, it must establish that the box labelled “Oranges” cannot be oranges or apples and must therefore be the mixed box. The remaining “Apples”-labelled box is then the oranges-only box. Qwen does not present the orange-drawn case with the same completeness.

The difference is not the initial insight—Qwen also identifies the right box—but the completeness of the deduction. This is a useful reminder that a correct answer can still be supported by an incomplete explanation.

Test 2 — Writing quality
#

All three new configurations produce coherent essays with a nuanced position, concrete examples, and a conclusion. Standard Nemotron makes a useful distinction between using technology to extend an existing skill and allowing a tool to replace that skill. DFlash produces a polished argument about the outsourcing of human capabilities to tools. Qwen’s response is thoughtful and detailed, but it uses a heading despite the instruction not to use headings or bullet points.

The shared weakness is length: the responses are appreciably shorter than the requested approximately 400 words. The writing is competent, but none is a perfect execution of the prompt. Standard Nemotron receives the highest score in this category, narrowly. This task also shows why fluent prose should be evaluated separately from reasoning and technical reliability.

Test 3 — Rust explanation and exact constraints
#

The rust task is useful because most of its requirements can be checked mechanically. Each response has exactly three paragraphs, places oxygen, water, and electrons in the first paragraph, includes one chemical equation in the second, uses an analogy in the third, and avoids the prohibited words. However, none reaches exactly 150 words.

Configuration Word count Equation Main issue
Nemotron + DFlash 125 Balanced overall equation 25 words short
Standard Nemotron 144 Balanced overall equation 6 words short
Qwen3.5 4B 146 Balanced hydrated-oxide equation 4 words short

The counts refer to the supplied response bodies, excluding the “Working time” line and treating chemical notation as whitespace-separated tokens. Standard Nemotron gives the most complete explanation while coming closest to the requested length. Qwen’s overall equation is balanced when the coefficient 2 is understood to multiply the entire hydrate formula, although its prose description of hydroxide formation is compressed. DFlash’s explanation is scientifically reasonable but misses the word-count requirement by a larger margin. The task illustrates how a response can satisfy nearly every structural condition and still fail an exact constraint.

Test 4 — Radical chemistry and spin states
#

This test requires a careful distinction between the doublet character of an individual radical and the combined singlet or triplet spin states of a radical pair. It also tests whether the response respects spin conservation when discussing the formation of an ordinary closed-shell covalent product. Two radicals are not automatically triplet-coupled, and a triplet radical pair cannot form an ordinary closed-shell singlet product directly without an appropriate route for spin evolution.

Qwen3.5 4B gives the most complete explanation of the three new configurations. It discusses bonding and antibonding combinations, distinguishes singlet and triplet radical-pair states, and mentions spin–orbit coupling and hyperfine-mediated mixing. Some wording is oversimplified: its reference to stabilization through “constructive interference” does not precisely explain the spin correlation and bonding process. Nevertheless, it covers more of the relevant physics than the Nemotron responses.

Nemotron + DFlash correctly identifies the singlet character of an ordinary closed-shell product and names spin–orbit coupling as a possible route to intersystem crossing (ISC). Its main conceptual weakness is the suggestion that radical pairs are often triplets by default because parallel alignment minimizes repulsion. A radical pair may be created in a singlet, a triplet, or a coherent mixture, depending on its formation pathway; triplet character cannot be assumed generically.

Standard Nemotron also recognises the singlet/triplet distinction and identifies ISC, but its treatment is less careful. It writes the product as A⁻B rather than the stated A–B and describes spin conversion as a generic spin flip without adequately discussing the pair’s spin Hamiltonian or the role of hyperfine interactions. Its explanation of ISC is serviceable but not especially deep.

None of the three responses provides a fully rigorous treatment. In particular, “triplet pair” is not a complete specification of the pair’s spin state. The actual spin evolution depends on the interactions and timescales in the chemical system, including the relevant hyperfine, exchange, and Zeeman contributions. Qwen receives the highest score in this category, but its answer still requires expert scrutiny.

Test 5 — Problem-solving: the 1,000-bottle puzzle
#

The correct strategy assigns each bottle a unique 10-bit binary code. Subject i receives a sample from every bottle whose ith bit is 1. After 24 hours, the pattern of deaths and survivors identifies the code of the poisoned bottle. Ten subjects are both necessary and sufficient because \(2^9 = 512 < 1000 \leq 2^{10} = 1024\).

Both Nemotron answers explain the binary encoding correctly. Standard Nemotron is especially clear about why nine subjects are insufficient and ten are sufficient. DFlash gives a concise, valid explanation of how the death/survival pattern decodes to the bottle number. Neither response supplies a worked example, but the central method is correct.

Qwen understands the general binary method, but its table contains a concrete assignment error: it assigns Bottle 1000, whose 10-bit code is 1111101000, to Subjects 1–9 and 10. That code does not have all ten bits set. The general bit-by-bit method is sound, but the incorrect table entry makes the answer unreliable as an implementation guide.

Standard Nemotron performs best in this test, with DFlash close behind. Qwen’s mistake does not invalidate the binary method as a whole, but it is an important encoding error in a task whose correctness depends on exact assignments.

Test 6 — Magnetic-field effects on chemical systems
#

This is the most important test for the intended scientific application. A useful answer must distinguish a radical-pair mechanism from generic magnetic-field dependence, represent spin evolution with an appropriate spin Hamiltonian or density-matrix treatment, include reaction kinetics, and propose controls that separate genuine magnetic effects from thermal changes and experimental artefacts.

Standard Nemotron gives the stronger of its two magnetic-field answers. It proposes kinetic or master equations, temperature-dependent rate constants, and field sweeps. However, it introduces field-dependent singlet–triplet conversion rates without deriving them from a defined spin model. References to Zeeman corrections and field-dependent spin energy do not replace the specification of a Hamiltonian, initial state, coherent evolution, relaxation, spin-selective reaction operators, and observables. The equations are also incomplete.

Nemotron + DFlash is weaker. It proposes singlet and triplet rate equations but leaves them as placeholders and suggests parameterising an ISC rate from Zeeman splitting. This risks conflating magnetic-field-driven radical-pair spin evolution with a generic field-dependent ISC rate. It also suggests that matching a calculated curve would confirm the magnetic-field effect; agreement with one curve is not enough to establish a mechanism.

Qwen provides the longest proposal and a Python code sketch, but it does not implement a valid radical-pair simulation. Its cosine dependence on field is an arbitrary illustrative function, not a result derived from a spin Hamiltonian. The thermal factor is multiplied into the yield without a justified kinetic scheme. The code calls random.gauss without importing random, and its “artefact probability” is an ad hoc score rather than a calibrated probability. Its concentration-linearity and oscillation heuristics are too simplistic to identify a mechanism. Most importantly, the code does not implement spin evolution from a Hamiltonian.

Gemma 4 E4B and E2B each scored 6/10 on this task in Part 1. None of the new answers improves on that baseline: standard Nemotron scores 4.0, DFlash 3.0, and Qwen 2.5. This is the clearest weakness across the new configurations and should matter more than surface fluency when selecting a model for the magnetic-field project.

The next scientific step should not be to request a generic “MFE simulation.” It should be to define a specific radical-pair system, its spin Hamiltonian, initial density matrix, spin-selective reaction channels, relaxation assumptions, and observables. Field-dependent yields can then be calculated numerically and compared with independent calculations and experimental controls. A model-generated outline or code sketch is not a substitute for this physically specified calculation.

4. Reasoning enabled versus disabled
#

The source records include both reasoning-enabled and reasoning-disabled responses for the new configurations. The reasoning-enabled responses have recorded elapsed times, while the reasoning-disabled responses are labelled Instant. The six-task scores in this article are based on the reasoning-enabled answers; the existing evaluation does not provide a separate scored table for the reasoning-disabled answers.

The available records therefore support a limited conclusion: disabling reasoning produced responses that the interface recorded as “Instant,” whereas reasoning-enabled runs took measurable time and generally supplied the longer explanations evaluated here. They do not establish a general numerical quality penalty or improvement from switching reasoning off. Such a claim would require a separate, consistent evaluation of both modes across all six tasks, using the same scoring rubric and a clearly defined timing method. “Instant” should not be interpreted as literal zero latency.

5. Speed comparison
#

The following table reports the recorded elapsed times for the six reasoning-enabled tasks. The Gemma figures are the Part 1 baselines.

Model / configuration Logic Writing Rust Radical chemistry Bottle puzzle Magnetic field Total Average per task
Gemma 4 E4B — baseline 1m 39s 46s 50s 50s 1m 06s 1m 22s 6m 33s 1m 06s
Gemma 4 E2B — baseline 37s 19s 11s 18s 34s 40s 2m 39s 27s
Nemotron 3.5 Bolt E4B 34s 26s 19s 21s 33s 44s 2m 57s 30s
Nemotron 3.5 Bolt E4B + DFlash 40s 17s 11s 13s 16s 27s 2m 04s 21s
Qwen3.5 4B 1m 09s 41s 1m 16s 32s 1m 09s 3m 48s 8m 35s 1m 26s

DFlash is the fastest configuration in this sample, completing the six tasks in 2m 04s, compared with 2m 39s for Gemma 4 E2B and 6m 33s for Gemma 4 E4B. That is approximately 1.28 times faster than E2B and 3.17 times faster than E4B in this particular run. Standard Nemotron completes the tasks in 2m 57s: slower than E2B but substantially faster than E4B. Qwen takes 8m 35s, the longest total in this comparison.

These are elapsed-time observations from individual runs, not token-per-second measurements or controlled throughput benchmarks. Output length, prompt processing, runtime configuration, and speculative-decoding behaviour can all affect the result. The timings describe what happened in this run; they do not isolate the cause of the speed differences or establish stable performance across repeated trials.

6. Quality versus resource cost
#

The practical observation recorded for this setup is that Nemotron + DFlash requires more memory and resources than the smaller Gemma 4 E2B configuration. That matters because its score advantage is modest: DFlash scores 7.00, compared with 6.67 for E2B. The benchmark therefore suggests a small quality gain and a noticeable speed gain, not a generational leap in answer quality.

The test record does not include measured RAM usage, VRAM usage, peak memory, GPU utilisation, or model-load footprint. It consequently does not quantify the resource penalty or support a quality-per-gigabyte calculation. The memory observation should be understood as a practical finding from use, not as a measured result in this benchmark. A useful follow-up measurement would record peak system RAM and VRAM for Gemma E2B, standard Nemotron, and Nemotron + DFlash under the same prompts and LM Studio settings.

7. Practical verdict
#

Model Verdict Best role suggested by this benchmark
Gemma 4 E2B Efficient lightweight option Everyday tasks when memory efficiency and responsiveness matter
Gemma 4 E4B Strong quality baseline Dependable small-model reference, particularly for logic and as the magnetic-field baseline
Nemotron 3.5 Bolt E4B Strongest new all-round result Fast general-purpose use; ties Gemma E4B’s six-task average in this sample
Nemotron 3.5 Bolt E4B + DFlash Fastest, with a resource trade-off High responsiveness when the additional memory cost is acceptable; overall quality is near Gemma E2B territory
Qwen3.5 4B Not a clear upgrade for this workload Useful writing and radical-chemistry coverage, but weak MFE modelling and avoidable reasoning or encoding errors

Standard Nemotron 3.5 Bolt E4B is the strongest new all-round candidate in this round: it ties Gemma 4 E4B’s 7.42 average while taking less than half the recorded time. Its weakness is scientific depth in the magnetic-field and radical-pair tasks, so the overall tie should not be mistaken for equivalence in every domain.

DFlash is the speed champion, but its 7.00 average is closer to Gemma 4 E2B’s 6.67 than to Gemma 4 E4B’s 7.42. If it consumes materially more memory, the practical decision depends on whether saving approximately 35 seconds across this six-task sample is worth that resource cost in the intended workflow. It may be attractive for routine short tasks, but its current scientific answers do not justify choosing it over Gemma on quality grounds.

Qwen3.5 4B is not a clear upgrade for this setup. Its radical-chemistry answer contains useful detail, but its magnetic-field code is not scientifically defensible, and other tasks reveal avoidable instruction-following or reasoning errors. Its 6.42 average also trails both Gemma baselines and standard Nemotron.

Final verdict
#

The expanded six-task benchmark identifies standard Nemotron 3.5 Bolt E4B and Gemma 4 E4B as joint leaders at 7.42/10 in this sample. Standard Nemotron is substantially faster in the recorded runs. DFlash scores 7.00/10 and is the fastest configuration, while Qwen3.5 4B scores 6.42/10 and takes the longest total time. The higher resource demand observed with DFlash is an important deployment consideration: its speed advantage and modest score improvement over Gemma E2B may not justify the memory cost for every use case.

The practical recommendation is to retain Gemma 4 E2B as the efficient lightweight option, consider standard Nemotron 3.5 Bolt E4B the most promising new general-purpose alternative, and use DFlash where its extra responsiveness is genuinely valuable and its resource cost is acceptable. For the magnetic-field-effects project, none of the models’ current answers should be treated as a simulation specification. The next meaningful step is a numerical test: provide each model with the same explicit radical-pair Hamiltonian and initial state, ask it to calculate a singlet or triplet yield over a defined field range, and compare its code and numerical output with an independently implemented Python reference calculation.